Back to Top

Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Pusat

Bergabung Selama :

BAGIKAN :   

Bagikan :
  • MESIN ANESTHESI - VENTILATOR - VAPORIZER " SHARP SHIN-EI JAPAN"

MESIN ANESTHESI - VENTILATOR - VAPORIZER SHARP SHIN-EI JAPAN

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0
Dilihat Sebanyak
:
138 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail MESIN ANESTHESI - VENTILATOR - VAPORIZER SHARP SHIN-EI JAPAN

MESIN ANESTHESI SHARP - VENTILATOR DAN VAPORIZER HALOTHANE - ISOFLURANCE -SEVOFLURANCE Anesthesia Apparatus SOFT LANDER SERIES SL-210 Compact, high reliability with functions equivalent to large machines. Setting Range of Flow Rate O2 Flow meter 0.1^ 10.0l/ min. N2O Flow meter 0.5^ 10.0l/ min Introductory Gas Pressure Gauge O2 Pressure Gauge 0^ 10kgf/ cm2 NO2 Pressure Gauge 0^ 10kgf/ cm2 Adjusting Pressure by O2 Pressure Regulator Pressure Regulator 4.2 0.5kg/ cm2 O2 Flush Flow Rate 35^ 75l/ min. O2 Supply Pressure Alarm 2.5 0.5kgf/ cm2 Canister Capacity 1100 50ml Dimensions H420 W445 D230min Weight 14.5kg Safety Device Relief Valve ( Safety Valve in the main part) Oxygen Ratio Controller O2 Supply Pressure Alarm N2O Cut-Off Valve SL-210 Components Main Body L-210  Option Vaporizers: HALOREX H-200 ISOREX I-200 Lung Pressure Gauge Respiratory Monitor Excess Gas Emission Unit GASTOL2 Changeover Switch Cock for Auto/ Manual respiration Ventilator SS-1200 Mobile Stand with Monitor Rack Anesthesia Ventilator & Other Optional Units Anesthetic Ventilator Lotus SS-1200 Electrically driven ventilator. It can be connected with an anesthetic apparatus generally sold. Ventilation Method Volume presets, time cycle Tidal Volume 100 to 1, 200ml Breathing Frequency 5 to 35bpm I/ E ratio I: E= 1: 2( fixed) Relief Valve 40cmH20 to 45cmH20( 3.92kPa to 4.41kPa) Bag meter -10cmH2O to 90cmH2O( -0.98kPa to 8.82kPa) Alarm Low Press, Over Range, Power Failure, CPU Trouble Power Requirement AC mains Dimensions H250 W410 D245mm Weight 15kg Respiratory Monitor The slight respiration will be accurately indicated with a lamp or buzzer. Dimensions H106 W224 D180mm Weight 1.75kg Excess Gas Emission Unit GASTOL 2 Connect the device with surplus gas suction port and exhaust the surplus gas outside Dimensions H89 W136 D227mm Weight 1.1kg Vaporizers Halothane ( H) , HALOREX H-200 Total Flow Rate of Carrier Gas 0.5 to 10 l/ min Capacity 200 30ml Dimensions H190 W129 D135min Weight 5.5kg Vaporizers Isoflurane ( I) , ISOREX I-200 Total Flow Rate of Carrier Gas 0.5 to 10 l/ min Capacity 200 30ml Dimensions H190 W129 D135min Weight 5.5kg Vaporizers Sevoflurane ( S) , SEVOREX S-200 Total Flow Rate of Carrier Gas 0.5 to 10 l/ min Capacity 200 30ml Dimensions H190 W129 D135min Weight 5.5kg http: / / youtu.be/ 789jtZ8tJgg
Tampilkan Lebih Banyak